Skip to main content
Back to Resources

Maintenance triage

CNC Alarm Category Table

Triage CNC alarms by category before reset, recovery, service dispatch, or downtime-cost review.

Direct answer: CNC alarms should be triaged by safety, servo, spindle, tool, coolant, program, and communication category before reset. Follow the builder manual and site lockout process.

Maintenance triage

CNC Alarm Category Table

Alarm-category triage table for separating safety, servo, spindle, tool, coolant, program, and communication issues before reset.

Source: Created from the 2026-06-24 error-code and maintenance support opportunity; always follow the control builder manual and site lockout procedure.Updated: 2026-06-24
Alarm categoryLikely systemFirst triage stepDo not reset until
Safety / E-stopDoor, interlock, E-stop, safety relayVerify people, guarding, and machine state.The unsafe condition is physically cleared.
Servo / axisDrive, encoder, following error, overtravelCheck axis position, obstruction, and drive message.Root cause is understood and travel is safe.
SpindleDrive, orientation, overload, chiller, lubricationCheck load, tool, coolant/chiller, and spindle status.Thermal or overload condition is cleared.
Tool / ATCMagazine, arm, tool pot, tool clampConfirm tool location, clamp state, and recovery procedure.Manual recovery procedure is complete.
Coolant / hydraulic / lubePump, pressure switch, tank, way lubeCheck fluid level, filter, pressure, and leaks.Pressure and lubrication are restored.
Program / macroCode, offset, macro variable, subprogramReview recent edit, modal state, and line number.The program path and offset state are verified.